Fire Alarm Control Panel
Fire Alarm Control Panel

Fire Alarm Control Panel

MOQ : 5 Units

Fire Alarm Control Panel Specification

  • Technology
  • Microcontroller Based Panel
  • Energy Efficiency Rating
  • Not Rated
  • Coverage Area
  • Depends on the number of zones (typically covers multiple zones in a building)
  • Coating Type
  • Powder Coated (Metal Enclosure)
  • Fire Class
  • A, B, C (Based on Connected Sensors)
  • Features
  • LCD Display, Fault and Alarm Indicators, Zone Wise Indication, Test/Reset Button, Local Sounder
  • Connectivity Type
  • Wired (Supports input from smoke/heat detectors and manual call points)
  • Installation Type
  • Wall Mounted
  • Working Temperature
  • 0C to 50C (typical for control panels)
  • Voltage
  • 230V AC, 50 Hz (Mains), with 24V Battery Backup
  • Shape
  • Rectangular
  • Mounting Type
  • Surface Mount
  • Control Type
  • Manual and Automatic
  • Application
  • Fire detection and alarm notification
  • Capacity
  • 2 to 4 Zone (as per model shown)
  • Reset Function
  • Front Panel Reset/Test Button
  • Output Relays
  • Alarm/Fire/Fault Relay Outputs for interfacing with other devices
  • Audible Alarm
  • Built-in Internal Buzzer
  • Display Type
  • Seven Segment LCD or LED
  • Indications
  • LED for Fire, Fault, Zone Status
  • Programming
  • Push Button Based (front keypad)
  • Sensor Compatibility
  • Works with Smoke, Heat Detectors and Manual Call Points
  • Enclosure Material
  • Metal (Powder Coated)
  • Number of Zones
  • 2 or 4 zones (expandable based on model)
  • Battery Backup
  • 24V Sealed Lead Acid Rechargeable Battery Support
  • Alarm Output
  • Buzzer and Relay contacts for external sounders
  • Test Mode
  • Yes, available via keypad
 

Fire Alarm Control Panel Trade Information

  • Minimum Order Quantity
  • 5 Units
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 100 Units Per Month
  • Delivery Time
  • 5-7 Days
  • Main Domestic Market
  • All India
 

Fire Alarm Control Panel About



Grab your ace Fire Alarm Control Panel-a grand, blue-ribbon solution for fire detection and alarm notification. With buzzer and relay contacts for external sounders, it supports 2 or 4 zones (expandable as per model) and 24V battery backup. Housed in a powder-coated metal enclosure, it features LED/LCD displays, user-friendly push-button programming, test/reset functions, and compatibility with key sensors. Whether you're a service provider, supplier, or trader in India, this panel ensures dependable protection-just Add to Cart for a special security advantage!

Advantages and Easy Operation of Fire Alarm Control Panel

Direction of use is simple-mount the panel, connect to smoke/heat detectors and manual call points, and program using the front keypad. Immediate notifications and alarm responses are ensured via built-in indicators and sounders. Advantage highlights include zone-wise monitoring, fast reset/test, and compatibility with diverse detectors. Competitive advantages feature microcontroller-based reliability, robust alarm/fault relays, and a secure powder-coated finish-essential for quick-fire response and building safety.


Supply Capability and Domestic Reach for Fire Alarm Control Panels

Stock ready for seamless delivery! We ensure steady supply and secure shipping to meet diverse project timelines across India. With reliable FOB Port options and strong logistics, your orders are handled efficiently. Our main domestic market spans major metropolitan and regional centers, ensuring prompt support for resellers and direct installations. Trust us for quality supply and timely distribution of fire alarm control panels wherever you need reliable building safety solutions.


FAQ's of Fire Alarm Control Panel:


Q: How does the Fire Alarm Control Panel operate during a fire incident?

A: The panel activates built-in buzzers and external sounders when it detects fire via connected smoke, heat detectors, or manual call points, promptly notifying occupants and triggering external alarms for effective evacuation.

Q: What sensors are compatible with this Fire Alarm Control Panel?

A: It is compatible with standard smoke detectors, heat detectors, and manual call points, allowing comprehensive fire detection coverage based on the installed environment's requirements.

Q: When should the Fire Alarm Control Panel's test/reset feature be used?

A: The test/reset function should be used during routine maintenance checks to verify operational readiness or immediately after resolving a fire or fault condition to reset the system to normal status.

Q: Where can this Fire Alarm Control Panel be installed?

A: Designed for wall mounting, it is suitable for commercial buildings, offices, factories, and other multi-zone structures where reliable fire detection and notification are essential.

Q: What are the key benefits of the panel's metal (powder-coated) enclosure?

A: The powder-coated metal enclosure provides robust protection against environmental factors, enhances durability, and ensures long-term reliability, making it ideal for demanding installation conditions.

Q: How does the panel's battery backup ensure continuous operation?

A: The 24V Sealed Lead Acid battery backup automatically powers the panel during mains failure, maintaining uninterrupted monitoring and alarm notification during power outages.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email



Back to top